Antibiotic resistance pattern of methicillin-resistant Staphylococcus aureus and Escherichia coli from mobile phones of healthcare workers in public hospitals in Ghana

Antibiotic resistance pattern of methicillin-resistant Staphylococcus aureus and Escherichia coli from mobile phones of healthcare workers in public hospitals in Ghana

Courage Kosi Setsoafia Saba1,&, Francis Naa-Inour2, Stephen Wilson Kpordze1

 

1Department of Biotechnology, Faculty of Agriculture, University for Development Studies, Tamale, Ghana, 2Department of Ecotourism and Environmental Management, Faculty of Natural Resources and Environment, University for Development Studies, Tamale, Ghana

 

 

&Corresponding author
Courage Kosi Setsoafia Saba, Department of Biotechnology, Faculty of Agriculture, University for Development Studies, Tamale, Ghana

 

 

Abstract

Introduction: mobile phone plays an essential role in the lives of healthcare professionals in hospitals as far as communication is concerned. However, it can also serve as a source of nosocomial infections. This study aimed at determining the prevalence and antibiotic susceptibility of Methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli isolated from mobile phones used by healthcare staff working in three public hospitals in Ghana.

 

Methods: in total, 220 swab samples were collected from 110 mobile phones of healthcare workers at a referral and two public tertiary hospitals in Ghana. Direct spreading of swab samples on agar plates was done. MacConkey agar and Baird Parker agar were used to isolate E. coli and S. aureus, respectively. Clinical Laboratory Standard Institute´s guidelines were followed for susceptibility testing, and S. aureus strains resistant to cefoxitin were considered to be MRSA. All E. coli and MRSA isolates were tested for their susceptibility to antibiotics using European Committee on Antimicrobial Susceptibility Testing (EUCAST) 2018 guidelines with its breakpoints. Obtained qualitative data were analyzed by using Microsoft Excel.

 

Results: of 110 mobile phones, 78 (70.9%) and 4 (3.6%) were colonized with S. aureus and E.coli, respectively. From the 78 S. aureus isolates, 22 (28%) isolates were MRSA. Fifty percent (50%) (11/22) of the MRSA isolates were multi-drug resistant, of which one isolate was resistant to all antibiotics tested. E. coli isolates had 100 resistances to both ceftriaxone and ceftazidime.

 

Conclusion: mobile phones used by healthcare workers in hospitals frequently harbor E. coli, S. aureus MRSA and may be sources of hospital-associated infections.

 

 

Introduction    Down

Staphylococcus aureus and E.coli along with their other species are both communal bacteria and opportunistic pathogens and their infections are common in low and middle income countries [1]. Approximately 30% of the human population is colonized with S. aureus [2] and the risk of developing this infection is increased in healthcare settings. In an estimate of every 100 hospitalized patients at any given time, seven in high-income and ten in low and middle income countries will acquire at least one hospital infection [3]. Methicillin-resistant S. aureus (MRSA) has emerged as a virulent pathogen and a leading cause of nosocomial infections [4], accounting for 20% to 80% of nosocomial infections [4]. Of current clinical concern, is the prevalence of multi-drug resistant MRSA in many parts of the world. In the United State (US), more than 40% of S.aureu blood stream infections are caused by MRSA [5]. In Europe, it ranges widely and the rates in the Mediterranean and United Kingdom (UK) exceed 30%, while the Netherlands and Scandinavian countries are approximately 2% [6]. Sources of these infections in hospitals include medical staff or colonized healthcare workers, colonized patients or patients´ own flora, contaminated environmental surfaces, and inanimate hospital objects [7]. Healthcare workers are increasingly exposed to colonized patients and, hence, more likely to be colonized with such infections than any ordinary person in the general population [8,9].

 

Several studies on clinicians´ mobile phones contamination in the USA and UK reported a level of overall mobile phone contamination (pathogenic and non-pathogenic organisms) ranging from 75% to 96%, with between 9% and 25% Methicillin-resistant S. aureus (MSSA), MRSA, E.coli [10,11]. E. coli, MRSA, and other virulent pathogens have been isolated from clinicians´ mobile phones; 98.6% MRSA has been detected from phones, hands, and ears of clinicians [11,12]. E. coli has been widely used as an indicator of fecal contamination instead of total coliform, which is more general and may include other environmental isolates. Therefore, E. coli was isolated as an indicator organism in this work to check if healthcare workers were practicing good hand hygiene. Little or no research has been conducted to assess bacteria on health workers´ mobile phones in Ghana. A previous study conducted by Saba et al. [13] assessed pathogens on door handles and other points of contact at the same hospitals considered in this study. The extent of knowledge about the potential of mobile phones to transmit infections among healthcare workers in Ghana was not known. This study, therefore, aimed at determining the antibiotic resistant profiles of S. aureus, Methicillin-resistant S. aureus (MRSA) and of E.coli isolates from mobile phones used by healthcare workers in three public hospitals in Ghana.

 

 

Methods Up    Down

Study design: the study was carried out at the three major government hospitals in the Tamale Metropolis of Ghana: i) Tamale Teaching Hospital (TTH): a referral hospital for three regions of Ghana, with 478 staff; ii) Tamale Central Hospital (TCH): a public tertiary healthcare facility with 156 beds and 442 staff; iii) Tamale West Hospital (TWH): a public tertiary healthcare center with 126 beds and 370 staff.

 

Sample size: samples were collected in March and April 2016. Permissions were granted by all three hospitals to conduct this research. Two hundred and twenty (220) swab (MEUS, Italy) samples were taken: 110 swabs for the isolation of S. aureus and 110 swabs for the isolation of E. coli. Samples were collected from the mobile phones of 110 healthcare workers. Out of the total 220 swab samples, 100 (50 mobile phones) were taken from the TTH, 60 (30 mobile phones) from TCH and 60 (30 mobile phones) from TWH. Mobile phones of health personnel at the administrative units were also swabbed as a control, since they do not have direct contact with patients. Individual sterile swabs moistened with sterile phosphate buffer saline (Oxoid, Hampshire, UK) were used to swab half the front and half the back surface of each mobile phone for E. coli isolation and the other half swabbed for S. aureus with a different swab. Two separate sterile swabs were used for each mobile phone, one for the isolation of S. aureus and the other for E. coli All samples were stored below 4°C and transported to the laboratory for analysis within 2 hours. All swab samples were then directly streaked onto MacConkey agar (Oxoid, Hampshire, UK) and Baird Parker agar (BioMerieux S.A, Spain), respectively for of E. coli and S. aureus. They were incubated for 24 hours at temperatures of 44.5°C and 37°C for E. coli and S. aureus, respectively. Suspected of E.coli colonies were further confirmed on Simmons citrate agar (Oxoid, Hampshire, UK) and incubated at 37°C for 24 hours. Pure cultures of E.coli and S. aureuswere made by plating positive colonies onto nutrient agar (Oxoid, Hampshire, UK), prior to the susceptibility testing of both organisms. Antibiotic susceptibility testing was performed and interpreted according to the Clinical and Laboratory Institute Standard (CLSI) guidelines [14] to determine the cefoxitin resistant S. aureus. The breakpoints were determined using National Committee for Clinical Laboratory Standards (NCCLS) document M31-A2 [15]. Methicillin-Resistant S. aureus strains were classified as those isolate resistant to cefoxitin (30 µg) (BioMerieux, Spain). Similarly, antibiotic susceptibility tests were also performed on the positive of E. coli and the MRSA isolates using the EUCAST, 2018 guidelines with its breakpoints. The antibiotics disks used for the E. coli isolates were ciprofloxacin (5 µg), gentamicin (10 µg), erythromycin (15 µg), ceftriaxone (30 µg), ceftazidime (10 µg) and nitrofurantoin (100 µg). For the susceptibility test of the MRSA isolates, the antibiotic disks used were ciprofloxacin (5 µg), gentamicin (10 µg), erythromycin (15 µg), tetracycline (30 µg), and chloramphenicol (30 µg). Multi-drug resistant isolates were classified as resistance to three or more antibiotics. All isolates have been stored in 25% glycerol at -20°C, and are available for future studies.

 

Statistical analysis: data obtained were analyzed using Microsoft Excel (Microsoft Office 2016). Results were enumerated in frequencies and percentages and presented in tables and charts.

 

 

Results Up    Down

Sources of S. aureus and E. coli: a total of 78 S. aureus isolates were cultured from 78 (70.9%) phones of the 110 mobiles phones sampled. Of the 78 S. aureus 58% (29/50) were from TTH, 80% (24/30) from TWH and 83% (25/30) from TCH (Table 1). Among the 110 samples collected for the isolation of E. coli from the 110 different mobile phones, there were no mobile phones contaminated at TWH and TCH, but 8% (4/50) of mobile phones from TTH were contaminated with E. coli. The phones contaminated with E. coli were found on mobiles phones of personnel from the following wards: administration, children´s, medical, and male wards. All mobile phones contaminated with E. coli were also contaminated with S. aureus

 

Determination of methicillin-resistant (MSRA) and methicillin-sensitive (MSSA) isolates using cefoxitin: antibiotic susceptibility tests were performed on the 78 positive S. aureus samples. Of the total 78 positive S. aureus isolates, 28% (22) isolates were resistant to cefoxitin while 72% (56) were susceptible. Twenty-eight percent (28%) of the isolates were, therefore, considered as MSRA while 72% were classified as MSSA. Of the 28% MRSA isolates, 45% (10), 41% (9), 14% (3) were from TTH, TCH and TWH, respectively (Table 2). Table 3 shows the wards in the various hospitals where MRSA were isolated.

 

Antibiotic resistance profile of MRSA isolates: fifty percent (11/22) of the MRSA isolates from the mobile phones were multi-drug resistant MRSA. One MRSA isolate, which was taken from a mobile phone on the female ward of the TCH, was resistant to all the five antibiotics (ciprofloxacin, gentamicin, erythromycin, tetracycline, and chloramphenicol) while another isolate, which was taken from the children´s ward of TCH, was resistant to four (gentamicin, erythromycin, tetracycline, and chloramphenicol) out of the five antibiotics tested (Table 4). Nine (9) of the 22 isolates were resistant to three antibiotics of which four were from the TTH (administration block, children´s, female and maternity wards), four from the TCH (administration block, OPD, male and labor wards) and one was from TWH (children´s ward) (Table 4). Six (27.3%) of the isolates were resistant to two antibiotics and three (13.6%) isolates were resistant to only one antibiotic. Twenty (90.9%) of the isolates were resistant to one or more antibiotics, while two isolates were susceptible to all the antibiotics used. Only one MRSA isolate (4.5%) was resistant to ciprofloxacin, two (9%) isolates were resistant to gentamicin, fourteen (63.6%) isolates were resistant to tetracycline, sixteen (72.72%) isolates were to erythromycin, and eighteen (81.82%) isolates were resistant to chloramphenicol. The highest resistance was recorded against chloramphenicol and the least was ciprofloxacin (Table 4). In Table 4 below shows the resistant profile of the MRSA and various hospital sources.

Antibiotic resistance pattern of the E. coli isolates: antibiotic susceptibility tests were performed on the four (3.4%) positive E.coli isolates using six different antibiotics (ciprofloxacin (5µg), gentamicin (10µg), erythromycin (15µg), ceftriaxone (30µg), ceftazidime (10µg) and nitrofurantoin (100µg). None of the isolates was exhibited multi-drug resistance. The resistant pattern can be found in Table 5. All the four (100%) isolates were resistant to both ceftriaxone and ceftazidime.

 

 

Discussion Up    Down

Our results provide an essential informative baseline on S. aureus, E. coli and MRSA on mobile phones belonging to healthcare workers of these hospitals in Ghana. There have been previous reports on the possibility of pathogens transmissions, not only by mobile phones, but also other electronic devices such as personal digital assistants, handheld computers, stethoscopes, which also included some epidemiologically important drug-resistant pathogens [16]. High level of S. aureus colonization in this study could be as a result of improper hand hygiene practice and irregular sensitization of mobile phones by these health workers as they come into contacts with colonized patients, surfaces, objects, and other objects in the hospital environments. This is in accordance with Katsuse-Kanayama et al. [17] and reinforces the need for proper hand hygiene practice by healthcare workers prior to patient contact as a critical way of avoiding healthcare-associated infections. Though the rate of E.coli contamination was low in our study, it is higher than the rates (0.98%) reported by Morubagal et al. [18] but similar to Rana et al. [19], where they reported 2%. Conversely, Tagoe et al. [20], Selim and Abaza [21], and Debnath et al. [22] had little higher rates of 8%, 13% and 14%, respectively. Contamination with E. coli means that other fecal coliforms and pathogens from healthcare workers´ mobile phones could be transmitted onto their hands and subsequently to the patients they serve or other common contact surfaces in the hospitals.

 

The MRSA isolation rate found in this study (28%) is higher than similar researches carried out. Oguzkaya-Artan et al. [23] recorded 0.95% rate of isolation in Turkey, 1.4% by Heyba et al. [24] in Kuwait, 11.7% by Smibert et al. [25] in Australia, and 13% by Pal et al. [26] in the UK. However, other researchers reported higher isolation rates such as 53% by Selim and Abaza [21] in Egypt, 37.5% by Chang et al. [27] in Taiwan, 73% by Iyer et al. [9] in Saudi Arabia, 33.9% by Shibabaw et al. [8] in Ethiopia and 53.3% by Angadi et al. [28] in India. Fifty percent (11/22) of the MRSA isolates from the mobile phones were multi-drug resistant MRSA isolates (Table 4). It is worrisome to find that an isolate from one of the mobile phones was resistant to all the antibiotics tested. There is a risk of resistant microbes and genes being possibly transferred to healthcare workers or patients. This could pose an increased financial burden on patients with low income status. These patients may be forced to resort to other advanced line antibiotic treatments, which are more expensive. Other previous studies did record higher percentages of E. coli contamination on mobile phones than our work [12,29]. Per the phenotypic resistance pattern, they may be similar or the same strains, but further work needs to be done to ascertain it. The presence of faeces on mobiles phones may be due to lack of cleanliness and low hygiene standards [22].

 

The antibiotic resistance profile of our study showed no multi-drug resistance (i.e. resistance to three or more antibiotics), but all the E.coli isolates were 100% resistant to both ceftazidime and ceftriaxone unlike other studies where they recorded 42.9% resistance to ceftazidime [22] and 50% resistance to ceftriaxone [18]. Our study also recorded 100% susceptibility to ciprofloxacin, gentamicin, erythromycin and nitrofurantoin but Debnath et al. [22] reported 42.9% and 57.1% resistance to both gentamicin and ciprofloxacin respectively in Bangladesh, and Morubagal et al. [18] reported 50% resistance to ciprofloxacin in Iran. However, our study had similar results with Gashaw et al. [30] who found E.coli isolates from healthcare workers´ mobile phones to be 100% sensitive to ciprofloxacin and gentamicin. On two of the mobile phones, both E.coli and MRSA were isolated. One mobile phone had ceftriaxone and ceftazidime resistant E.coli and erythromycin, tetracycline and chloramphenicol resistant MRSA. The other mobile phone had E.coli resistant to ceftriaxone and ceftazidime, but the MRSA isolate from it was susceptible to all the antibiotics used. Further molecular characterization of these strains is required to understand the resistance dynamics, which was a limitation of this particular research.

 

Limitations of the study: it would have been relevant to extend the study to smaller and/or private hospitals. This study was limited to public hospitals at Tamale metropolis. Careful consideration should be taken to avoid generalizing the findings to all hospitals in Tamale metropolis. Data limitation on sample size was a major obstacle, especially from Ghana. The researchers used journals for information on Africa, and relied on the little available literature that was available for estimation. The study employed conventional approach instead of molecular (PCR) methods that are known to be highly specific. To overcome this, Baired Parker supplemented with Rabbit Plasma Fibrinogen (RPF) which makes it highly selective for S. aureus isolation, and use of biochemical confirmation were employed for the study.

 

 

Conclusion Up    Down

This study is the first to focus on contamination of healthcare workers´ mobile phones with E. coli and S. aureus in Ghana. In three hospitals in Tamale, health worker´s phones recorded very low colonization of E. coli but there was high prevalence with S. aureus exhibiting relatively high rates of MRSA that presented various resistance patterns to the antibiotic used in the study. Health workers´ mobile phones may serve as a source of transmission of MRSA to patients. Awareness creation on the potential for mobile phones to spread diseases in the hospital setting, alongside with intensive programs on infection prevention and control in hospitals, is recommended.

What is known about this topic

  • Presence of E.coli on fomites indicates fresh faecal contamination;
  • Staphylococcus aureus is among the leading isolates in nosocomial infections;
  • Methicillin-resistant S. aureus strains are resistance to multiple drugs.

What this study adds

  • Our study allowed us to have current data on the MRSA and E. coli prevalence on healthcare workers' mobile phones (rates of 28% MRSA and 0.98% E. coli) in three main public hospitals in the Northern region of Ghana;
  • Some healthcare workers had their mobile phones contaminated with fresh faeces (presence of E. coli); however, these isolates were not multidrug resistant;
  • This study discovered the high level of colonization of health workers' mobile phones with MRSA isolates, which are multi-drug resistant; these results will be very useful to the hospitals' infection prevention and control (IPC) departments to take significant measures to curb the spread of nosocomial diseases.

 

 

Competing interests Up    Down

The authors declare no competing interests.

 

 

Authors' contributions Up    Down

Courage Kosi Setsoafia Saba: designed, wrote and critically revised the manuscript; Francis Naa-Inour: was involved in the laboratory analysis; Stephen Wilson Kpordze: was involved in the laboratory analysis and also wrote the manuscript. All authors read and approved the final manuscript.

 

 

Acknowledgments Up    Down

We are indebted to the University for Development Studies, Tamale, Ghana for permitting us to use the Spanish Laboratory Complex for this work. Our thanks also go to Prof. Bruno Gonzalez-Zorn and Miss Natalia Montero from the Complutense University of Madrid, Spain for facilitating the purchase of materials for this research work. We appreciate very much the efforts of all the staff from the various hospitals that made this work a success.

 

 

Tables Up    Down

Table 1: prevalence of S. aureus on mobile phones at the various departments/wards at each hospital

Table 2: methicillin-resistant Staphylococcus aureus and MSSA prevalence on mobile phones in the various hospitals

Table 3: wards/departments of personnel at the time samples were taken

Table 4: antibiotic resistant profile of MRSA and their sources

Table 5: resistance pattern of isolated E. coli

 

 

References Up    Down

  1. Allegranzi B, Bagheri Nejad S, Combescure C, Graafmans W, Attar H, Donaldson L et al. Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysis. Lancet. 2011 Jan 15;377(9761):228-41. PubMed | Google Scholar

  2. Wertheim HF, Melles DC, Vos MC, van Leeuwen W, van Belkum A, Verbrugh HD et al. The role of nasal carriage in S. aureus infections. Lancet Infect Dis. 2005 Dec;5(12):751-626. PubMed | Google Scholar

  3. World Health Organization. Report on the burden of endemic health care-associated infection worldwide. 2011. Google Scholar

  4. David MZ, Daum RS. Community-associated methicillin resistant S. aureus: epidemiology and clinical consequences of an emerging epidemic. Clin Microbiol Rev. 2010 Jul;23(3):616-87. PubMed | Google Scholar

  5. Styers D, Sheehan DJ, Hogan P, Sahm DF. Laboratory-based surveillance of current antimicrobial resistance patterns and trends among S. aureus: 2005 status in the United States. Ann Clin Microbiol Antimicrob. 2006 Feb 9;5:2. PubMed | Google Scholar

  6. European Centre for Disease Prevention and Control. Antimicrobial resistance surveillance in Europe 2009. Accessed on 17 Nov, 2018.

  7. Marshal BM, Ochieng DJ, Levy SB. Commensals: unappreciated reservoir of antibiotic resistance probing the role of commensals in propagating antibiotic resistance should help preserve the efficacy of these critical drugs. Accessed on 9 April, 2017.

  8. Shibabaw A, Abebe T, Mihret A. Nasal carriage rate of methicillin-resistant S. aureus among Dessie referral hospital healthcare workers; Dessie Northeast, Ethiopia. Antimicrob Resist Infect Control. 2013 Oct 2;2(1):25. PubMed | Google Scholar

  9. Iyer A, Kumosani T, Azhar E, Barbour E, Harakeh S. High incidence rate of methicillin-resistant S. aureus among healthcare workers in Saudi Arabia. J Infect Dev Ctries. 2014 Mar 13;8(3):372-8. PubMed | Google Scholar

  10. Beer D, Vandermeer B, Brosnikoff C, Shokoples S, Rennie R, Forgie S. Bacterial contamination of health care workers´ pagers and the efficacy of various disinfecting agents. Pediatr Infect Dis J. 2006 Nov;25(11):1074-5. PubMed | Google Scholar

  11. Brady RR, Verran J, Damani NN, Gibb AP. Review of mobile communication devices as potential reservoirs of nosocomial pathogens. J Hosp Infect. 2009 Apr;71(4):295-300 PubMed | Google Scholar

  12. Osman MB, Omer SM, Almugadam BS, Ahmed HM. Frequency of MRSA isolates in mobile phones, ears and hands of healthcare workers. J Antimicrob Agents. 2018;4(161):2472-1212. Google Scholar

  13. Saba CKS, Amenyona JK, Kpordze SW. Prevalence and pattern of antibiotic resistance of S. aureus isolated from door handles and other points of contact in public hospitals in Ghana. Antimicrob Resist Infect Control. 2017 May 10;6:44. PubMed | Google Scholar

  14. Clinical and Laboratory Standards Institute. Performance standards for antimicrobial susceptibility testing; twenty-fourth informational supplement. Accessed on May 23, 2017.

  15. National Committee for Clinical Laboratory Standards (NCCLS). Performance standards for antimicrobial disk and dilution susceptibility tests for bacteria isolated from animals; approved standard-3rd edition. 2002;28(8).

  16. Isaacs D, Daley A, Dalton D. Swabbing computers in search of nosocomial bacteria. Pediatr Infect Dis J. 1998 Jun;17(6):533. PubMed | Google Scholar

  17. Katsuse-Kanayama A, Takahashi H, Yoshizawa S, Tateda K, Kaneko A, Kobayashi I. S. aureus surface contamination of mobile phones and presence of genetically identical strains on the hands of nursing personnel. Am J Infect Control. 2017 Aug 1;45(8):929-931. PubMed | Google Scholar

  18. Morubagal RR, Shivappa SG, Mahale RP, Neelambike SM. Study of bacterial flora associated with mobile phones of healthcare workers and non-healthcare workers. Iran J Microbiol. 2017 Jun;9(3):143-151. PubMed | Google Scholar

  19. Rana R, Joshi S, Lakhani S, Kaur M, Patel P. Cell phones-homes for microbes. Int J Biol Med Res. 2013;4(3):3403-6. Google Scholar

  20. Tagoe DN, Gyande VK, Ansah EO. Bacterial contamination of mobile phones: when your mobile phone could transmit more than just a cell. Webmed Cent Microbiol. 2011;2(10). Google Scholar

  21. Selim HS, Abaza AF. Microbial contamination of mobile phones in a health care setting in Alexandria, Egypt. GMS Hyg Infect Control. 2015 Feb 2;10:Doc03. PubMed | Google Scholar

  22. Debnath T, Bhowmik S, Islam T, Hassan-Chowdhury MM. Presence of multidrug-resistant bacteria on mobile phones of healthcare workers accelerates the spread of nosocomial infection and regarded as a threat to public health in Bangladesh. J Microsc Ultrastruct. Jul-Sep 2018;6(3):165-169. PubMed

  23. Oguzkaya-Artan M, Baykan Z, Artan C, Avsarogullari L. Prevalence and risk factors for methicillin resistant S. aureus carriage among emergency department workers and bacterial contamination on touch surfaces in Erciyes University Hospital, Kayseri, Turkey. Afri Health Sci. 2015;15(4):1289-1294. PubMed | Google Scholar

  24. Heyba M, Ismaiel M, Alotaibi A, Mahmoud M, Baqer H, Safar A et al. Microbiological contamination of mobile phones of clinicians in intensive care units and neonatal care units in public hospitals in Kuwait. BMC Infect Dis. 2015 Oct 15;15:434 PubMed | Google Scholar

  25. Smibert OC, Aung AK, Woolnough E, Carter GP, Schultz MB, Howden BP et al. Mobile phones and computer keyboards: unlikely reservoirs of multidrug-resistant organisms in the tertiary intensive care unit. J Hosp Infect. 2018 Jul;99(3):295-298. PubMed | Google Scholar

  26. Pal P, Roy A, Moore G, Muzslay M, Lee E, Alder S et al. Keypad mobile phones are associated with a significant increased risk of microbial contamination compared to touch screen phones. J Infect Prev. 2013 Mar;14(2):65-8. Google Scholar

  27. Chang CH, Chen SY, Lu JJ, Chang CJ, Chang Y, Hsieh PH. Nasal colonization and bacterial contamination of mobile phones carried by medical staff in the operating room. PLoS One. 2017 May 31;12(5):e0175811. PubMed | Google Scholar

  28. Angadi KM, Misra R, Gupta U, Jadhav S, Sardar M. Study of the role of mobile phones in the transmission of Hospital acquired infections. Med J D.Y. Patil Univ. 2014 Jul 1;7(4):435. Google Scholar

  29. Raghavendra MP, Shruthi KC, Shivalingaiah B. Bacteriological screening of hands and mobile phones of healthcare workers and its management. Int J Recent Trends Sci Technol. 2014;4(1):92-97.

  30. Gashaw M, Abtew D, Addis Z. Prevalence and antimicrobial susceptibility pattern of bacteria isolated from mobile phones of health care professionals working in Gondar town health centers. ISRN Public Health. 2014;1:6. Google Scholar