Home | Volume 38 | Article number 219

Case report

Small residual patent ductus arteriosus after surgical ligation in young adult: to close or not to close - a dilemmatic case report

Small residual patent ductus arteriosus after surgical ligation in young adult: to close or not to close - a dilemmatic case report

Alexander Edo Tondas1,2,&, Rido Mulawarman3, Monica Trifitriana3, Moza Guyanto3, Raymond Pranata4, Komaria1

 

1Department of Cardiology and Vascular Medicine, Mohammad Hoesin General Hospital, Palembang, Sumatera Selatan, Indonesia, 2Biomedicine Doctoral Program, Faculty of Medicine, Universitas Sriwijaya, Palembang, Indonesia, 3Faculty of Medicine, Universitas Sriwijaya Palembang, Indonesia, 4Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia

 

 

&Corresponding author
Alexander Edo Tondas, Department of Cardiology and Vascular Medicine, Mohammad Hoesin General Hospital, Palembang, Sumatera Selatan, Indonesia

 

 

Abstract

Percutaneous transcatheter closure has gained acceptance for patent ductus arteriosus (PDA) management ever since its introduction, including the management residual left- to-right shunt following surgical ligations. It is preferred than the more invasive surgical closure. While large PDA is closed to prevent heart failure, the decision to close a small hemodynamically insignificant PDA is still a debatable issue. We present a case of percutaneous transcatheter closure of small residual left-to-right shunt PDA using HeartR™ Lifetech PDA occluder with instantaneous closure in an asymptomatic adult patient. The justification of closure was made based on the previous history of infective endocarditis, followed by PDA ligation and endarterectomy surgery, at 1.5 year before admission.

 

 

Introduction    Down

Residual shunt after patent ductus arteriosus (PDA) ligation has been reported to be roughly 6%, as a result from sub-optimal occlusion or recanalization of a totally occluded ductus [1]. Historically, infective endocarditis (IE) was a rare but often fatal complication of PDA, therefore, closure of hemodynamically insignificant small PDA is still a debatable issue [2,3]. Despite the successes of the first approved device Amplatzer™ duct occluder (ADO), new devices with different structural characteristics have been produced [4,5]. In this case, the HeartR™ PDA occluder (Lifetech Scientific Co, Ltd., Shenzhen, China) was used to close a small residual PDA in a young adult.

 

 

Patient and observation Up    Down

A 28-year-old male patient with a history of premature birth had undergone PDA ligation and endarterectomy 1.5 years ago on a large, type A, left-to-right shunt PDA with 7 mm diameter, which was diagnosed later in adulthood, due to lack of awareness. The decision for open heart surgery was made in consideration of vegetation growth in the main pulmonary artery (MPA) side of the PDA noticed by echocardiography, and obvious clinical signs of definite infective endocarditis. After the procedure, left ventricular (LV) ejection fraction was 59% and functional class improved from New York Heart Association (NYHA) III to NYHA I. Medications to control heart failure such as angiotensin converting enzyme (ACE) inhibitor, beta blocker and spironolactone was titrated according to clinical development.

 

The patient came back to us for his annual check-up visit, and was presented without any notable symptom except atypical chest discomfort. However, 2-dimensional echo exam revealed a persistent small residual PDA, 3-4 mm in diameter, with left-to-right shunt (Figure 1). After informed consent, transcatheter device closure was planned in concern of IE relapse. Under sedation, antegrade access was obtained via the right femoral vein and retrograde access was obtained via the right femoral artery. An initial angiography was performed with a 5F pigtail catheter positioned in the proximal descending aorta with lateral and 30o right anterior oblique (RAO) projections. A 0.035” wire was used to cross the PDA and delivered into the main pulmonary artery (MPA). Cardiac catheterization measurements calculated FR of 1, PARi of 1.13 WU/m2, and PVR/SVR of 0.32. Angiography from descending aorta (AoD) revealed type A PDA with 3.4 mm isthmus diameter and 17.31 mm ampulla size (Figure 2). Subsequently, 8/10 mm HeartR™ PDA occluder (Life-Tech Sciences) was deployed across PDA anterogradely. After confirming the shunt closure by two-dimensional echocardiogram and descending thoracic aortogram, the delivery system was removed retrogradely. The procedure was successful without any meaningful complication. Fluoroscopy time was 10 minutes and 29 seconds. Echocardiography evaluation directly after closure showed no residual shunt and acceptable device position. Post-procedural course was uneventful, and no residual PDA was observed until one year follow up of this patient.

 

 

Discussion Up    Down

Patent ductus arteriosus in adults is a rare case compared to PDA in infants and early childhood with only 0,05% prevalence [6]. Residual shunts in post ligation PDA can occur in approximately 6% of cases. Even though spontaneous closure of silent PDA might occur within 3-6 months, 7% of patients will require a second procedure to close the shunt [7]. Patients with a small and hemodynamically insignificant PDA often remain asymptomatic and may never develop symptoms. However, regardless of the size, complications may arise; most importantly IE. As previously mentioned, the incidence of IE in PDA is very rare; however, this incidence may be higher in some developing countries due to nonexistent mechanisms of prevention, delay in seeking treatment due to poor financial status, lack of a proper health delivery system, and poor knowledge of how to treat fever in patients with underlying heart disease [8]. The decision to close small and hemodynamically insignificant PDA for the sole purpose of preventing the very rare incidence of IE is still debatable with many authors. Many suggest not to close the small PDA due to the rare incidence of IE and higher risk than benefit, while others prefer to close the PDA since IE is a fatal complication that can result in patient´s death if not treated adequately and in time. Infective endocarditis is also responsible for almost half of deaths in patients with untreated PDA [3,9]. Considering the fatality of IE should it occur and the patient´s previous history of IE, we decided to close the PDA.

 

Closure of PDA in cardiac catheterization laboratory is preferred to surgery in most cases since the latter is more invasive and mandates the use of inhaled anesthetic agents for general anesthesia. Several factors determine the success of percutaneous device closure of PDA including vascular accessibility, size and morphology of the duct, and device selection [6]. Transcatheter closure of PDA usually employs either coils or nitinol-based devices [10]. Amplatzer Duct Occluder (ADO) is the most commonly used device with excellent occlusion rates (99%-100%) and a low incidence of complications (0-7%) [4]. In this case, we use HeartR™, the first generation of Lifetech PDA occluder as the device to close the small residual PDA. This device is made of 0.004 nitinol wire mesh and shaped similar to ADO; however, the polyester fabric in the ADO device was replaced by expanded polytetrafluoroethylene (ePTFE) membrane to promote instantaneous closure of the duct and thereby eliminate residual flows. The foaming of the blood through the polyester fabric of ADO usually results in a continued left-to-right color Doppler flow, which is difficult to differentiate from a residual flow, due to incomplete device apposition to the ampulla. The absence of blood foaming across ePTFE in HeartRTM occluder aids the immediate echocardiographic assessment of device deployment. Even though the ePTFE material caused significant acoustic shadowing beyond the device giving poor views of the descending aorta; the identification of residual flows, if any, was easier in the anteriorly placed pulmonary arteries [10].

 

 

Conclusion Up    Down

In conclusion, the closure of a small residual PDA from previous surgical ligation may be justified in susceptible patients with past history of infective endocarditis. The usage of transcatheter devices made from ePTFE material can assist operators in the judgement of immediate closure after deployment.

 

 

Competing interests Up    Down

The authors declare no competing interests.

 

 

Authors' contributions Up    Down

AET managed the patient, drafted the manuscript, and performed literature search. RM and MT drafted the manuscript and performed literature search. RP and K performed manuscript review and editing. All authors contributed to the writing of the manuscript; they read and approved the final version of the manuscript.

 

 

Figures Up    Down

Figure 1: two-dimensional echocardiography showed the small residual PDA

Figure 2: final angiography post PDA closure with HeartR™ device

 

 

References Up    Down

  1. Sudhakar BGK. Percutaneous transcatheter closure of a distorted residual patent ductus arteriosus post surgical ligation using retrograde wiring and femoral arterio-venous loop technique- a case report. IHJ Cardiovasc Case Reports. 2018;2(3):208-210. Google Scholar

  2. Kuijpers JM, Koolbergen DR, Groenink M, Peels KCH, Reichert CLA, Post MC et al. Incidence, risk factors, and predictors of infective endocarditis in adult congenital heart disease: Focus on the use of prosthetic material. Eur Heart J. 2017;38(26):2048-2056. PubMed | Google Scholar

  3. Fortescue EB, Lock JE, Galvin T, McElhinney DB. To close or not to close: the very small patent ductus arteriosus. Congenit Heart Dis. 2010;5(4):354-365. PubMed | Google Scholar

  4. Chamié F, Simões LC, de Queiroz DSC, Mattos R. Percutaneous closure of a patent ductus arteriosus with the CeraTM PDA occluder: another good option in the Toolbox. Rev Bras Cardiol Invasiva English Version. 2012;20(1):77-81. Google Scholar

  5. Elmarsafawy H, Matter M, Abo-Haded HM, Rakha S, Hafez MM, Alsawah GA et al. Transcatheter closure of patent ductus arteriosus, evaluating the outcome: single center experience in Mansoura, Egypt. Prog Pediatr Cardiol. 2019;52:33-38. Google Scholar

  6. Jose PSJ, George OK. Contemporary outcomes of percutaneous closure of patent ductus arteriosus in adolescents and adults. Indian Heart J. 2018;70(2):308-315. PubMed | Google Scholar

  7. Liang C Di, Ko SF, Huang CF, Chien SJ, Lin YJ, Lin IC et al. Immediate echocardiographic surveillance after transcatheter closure of a patent ductus arteriosus: a feasible method to assess residual Shunt. Pediatr Neonatol. 2010 Feb;51(1):52-6. PubMed | Google Scholar

  8. Sadiq M, Latif F, Ur-Rehman A. Analysis of infective endarteritis in patent ductus arteriosus. Am J Cardiol. 2004;93(4):513-515. PubMed | Google Scholar

  9. Wiyono SA, Witsenburg M, De Jaegere PPT, Roos-Hesselink JW. Patent ductus arteriosus in adults: Case report and review illustrating the spectrum of the disease. Netherlands Hear J. 2008;16(7-8):255-259. PubMed | Google Scholar

  10. Sivakumar K, Bhagyavathy A, Gnanapragasam F. Closure of large patent ductus arteriosus in renal failure under echocardiographic guidance without use of radiographic contrast media. Congenit Heart Dis. 2009;4(1):59-62. PubMed | Google Scholar