Early experience with permanent pacemaker implantation at a tertiary hospital in Nigeria
Uvie Ufuoma Onakpoya, Olugbenga Olalekan Ojo, Oghenevware Joel Eyekpegha, Abayomi Emmanuel Oguns, Anthony Olubunmi Akintomide
Corresponding author: Olugbenga Olalekan Ojo, Department of Surgery, College of Health Sciences, Obafemi Awolowo University, Obafemi Awolowo University Teaching Hospital, Ile-ife, Nigeria
Received: 19 Jun 2020 - Accepted: 20 Jun 2020 - Published: 13 Jul 2020
Domain: Cardiology,Cardiovascular surgery
Keywords: Pacemaker, bradyarrhythmia, complete heart block, single chamber (VVIR), dual chamber (DDDR)
©Uvie Ufuoma Onakpoya et al. Pan African Medical Journal (ISSN: 1937-8688). This is an Open Access article distributed under the terms of the Creative Commons Attribution International 4.0 License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Cite this article: Uvie Ufuoma Onakpoya et al. Early experience with permanent pacemaker implantation at a tertiary hospital in Nigeria. Pan African Medical Journal. 2020;36:177. [doi: 10.11604/pamj.2020.36.177.24425]
Available online at: https://www.panafrican-med-journal.com//content/article/36/177/full
Early experience with permanent pacemaker implantation at a tertiary hospital in Nigeria
Uvie Ufuoma Onakpoya1, Olugbenga Olalekan Ojo1,&, Oghenevware Joel Eyekpegha2, Abayomi Emmanuel Oguns2, Anthony Olubunmi Akintomide3
&Corresponding author
Introduction: artificial pacemakers generate electrical impulses and regulate the heart´s conduction system. They are often used to treat individuals with bradycardia. Permanent pacemaker implantation is a lifesaving procedure especially in patients with symptomatic bradyarrhythmias. The objectives was to evaluate the clinical attributes and outcomes of permanent pacemaker implantation in Ile-ife, Nigeria.
Methods: we retrospectively reviewed medical records of 22 patients who had pacemaker implantation from January 2015 to December 2019. Patient´s demographics, clinical presentation, diagnosis, comorbidities, type of device, complications and long-term follow up were studied.
Results: sixteen males (72.7%) and 6 females (27.3%) were recruited into the study with ages ranging between 54 and 84 years and a mean of 70.3 +8.7 years. The commonest symptom was easy fatigability (45.5%) followed by syncope (31.8%). The main indication for permanent pacemaker implantation was complete heart block (86.4%). Seventeen (77.3%) patients had hypertension as the comorbidity present at diagnosis. Single chamber (VVIR) pacemaker was implanted in 13(59.1%) patients while dual chamber (DDDR) was implanted in 9(40.9%) patients. Hematoma, pneumothorax and acute lead dislodgement were the complications observed in 3 patients. There was no statistical significance between the type of device implanted and the occurrence of complications, p-value 0. 186. There was no mortality and 15 patients (68.2%) are currently attending regular 6 monthly follow-up.
Conclusion: complete heart block is the most common indication for permanent pacemaker implantation and the procedure is safe with minimal complications and satisfactory outcomes.
Permanent pacemaker implantation (PPI) is a lifesaving procedure especially in patients with bradyarrhythmias. Bradyarrhythmias are most commonly caused by failure of impulse formation (sinus node dysfunction) or by failure of impulse conduction over the atrioventricular (AV) node/His-Purkinje system [1]. Amongst the various AV conduction abnormalities, complete third-degree AV block (AVB) with or without symptoms has been demonstrated to be the most common indication for pacemaker implantation in Nigeria and West Africa at large [2-4]. Sinus node dysfunction otherwise known as Sick sinus syndrome is the predominant indication for cardiac pacing in Western population [5]. Other indications for permanent pacemaker implantation include; symptomatic second degree AV bock (Mobitz type I and II),chronic bi-fascicular block, persistent second degree AV block post myocardial infarction, neurocardiogenic syncope etc. In the paediatric age group, congenital complete heart block and more often persistent heart block post cardiac surgical interventions are prominent indications for permanent pacemaker implantation. Since the introduction of transvenous endocardial pacing in 1958, the field of cardiac pacing has benefited greatly from advances made in electronics, computer technology, power sources, and miniaturization [1]. There has been an increasing number of indications for cardiac device implantation including permanent pacemakers over the years [6, 7] and this has become evident in our environment too [3, 8]. Most permanent pacemakers are implanted tranvenously under local anaesthesia with or without sedation via the cephalic, axillary or subclavian veins. The cephalic access is achieved via a cut down technique and this route avoids the risk of pneumothorax which can occur with the subclavian puncture technique. This technique however requires a patent cephalic vein, which is not always the case in older patients and theoretically the relative extensive dissection when compared to a medial subclavian puncture might lead to a higher incidence of pacemaker pocket hematoma. The axillary vein route for transvenous pacemaker implantation avoids the narrow costoclavicular angle which is a potential spot for pacemaker lead compression/fracture when employing the subclavian puncture technique. Regardless of the access vein for transvenous endocardial pacing, notable procedural and immediate post procedure complications of permanent pacemaker implantation include; pneumothorax, hemothorax, air embolism, cardiac perforation, pacemaker pocket hematoma, pocket site infection, acute lead dislodgement, diaphragmatic pacing and sepsis. The aim of our study is to evaluate the clinical attributes and early outcomes of permanent pacemaker implantation in a tertiary hospital in Nigeria.
This was a retrospective study of patients who underwent primary transvenous permanent pacemaker implantation for various indications between January 2015 and December 2019 at our federally funded Teaching Hospital. All the patients in this study had transvenous permanent pacemaker implantation under local anesthesia. The Seldinger puncture technique was used to access the subclavian vein and the left subclavian vein was our first choice. Patients requiring secondary implantation and change of pacemaker pulse generator were exempted from this study. Patient´s demographics, clinical presentation, diagnosis, comorbidities, type of device, complications, and long-term follow up were studied. Data was obtained from the hospital medical records and analyzed with the SPSS statistical package (version 16.0). The student t test was used to compare continuous variables and the χ2 or Fischer´s exact test for categorical variables. A p value of < 0.05 was considered statistically significant.
Twenty-two patients had permanent pacemaker implantation (PPI) during the 5-year review period. There were 16 males (72.7%) and 6 females (27.3%) in the study. The age range was between 54-84 years with a mean of 70.3 +8.7. The most common symptom at presentation was easy fatigability occurring in 10(45.5%) patients followed by syncope 7(31.8%) (Table 1). Complete heart block was the most common indication for permanent pacemaker implantation, and this was observed in 19(86.4%) patients. Most patients had hypertension 17(77.3%) as the comorbidity present at implantation, 2(9.1%) patients had both hypertension and diabetes mellitus. Single chamber (VVIR) pacemaker was implanted in 13(59.1%) patients while dual chamber (DDDR) was implanted in 9(40.9%) patients. Pacemaker pocket hematoma, pneumothorax and acute lead dislodgement were the complications observed in 3 patients (Table 1). There was no statistical significance between the type of device implanted and the occurrence of complications, p-value 0.186 (Fisher´s exact) Table 2. There was no in-hospital or 30 day mortality, all patients attended follow-up clinics up to 6 weeks post procedure, 6 patients have been transferred out to the referring hospital for continuation of post device care and 1 patient was lost to follow up. Fifteen patients (68.2%) are currently attending regular 6 monthly follow-up clinics at our hospital.
The male preponderance in our patients is in keeping with reports in other studies [5, 9, 10] while the mean age of patients in this study was 70.3 +8.7 with most patients between the ages of 70-79 years (40.9%). This is consistent with findings in other studies and also shows the increasing need of pacemaker implantation in older patients [3, 11, 12]. The most common symptom at presentation was easy fatigability occurring in 10 (45.5%) patients followed by syncope in seven (31.8%) patients which is at variance with findings in other studies [11, 13]. In the study by Aktoz et al. [11] syncope was the main symptom in patients requiring permanent pacemaker implantation. Falase et al. [13] also found syncope (49%) as the most common clinical indication for permanent pacemaker insertion. This difference might be due to the fact that our study population is small. It remains to be seen if this trend will change in our subsequent studies with larger patient numbers towards what obtains in most other studies. Complete heart block was the most common indication for permanent pacemaker implantation. This has also been demonstrated in a vast majority of studies [2, 3, 10, 11, 14]. Hypertension was the most frequent co-morbidity in this study, which is consistent with previous findings in our environment [8, 10]. One patient suffered a stroke while waiting to accept the need for a permanent pacemaker implantation. Thomas et al. [8] had earlier admonished attending physicians of the need to balance medications to ensure an adequate and sustained blood flow to the vital organs like the brain and kidneys. The stroke in this patient could have been due to aggressive pharmacological lowering of the patient´s blood pressure. Single chamber (VVIR) pacemaker was implanted in almost two-thirds of patients while the rest had dual chamber implantation. The higher number VVIR mode in our study is in keeping with the findings of Aktoz et al. [11] and most reports from West Africa [2, 3, 15]. The choice of pacemaker mode/type in our patients was initially influenced by the cost because; the dual chamber device was far more expensive than the single chamber device until recent times when the cost difference was reduced by the manufacturers. This has led to a recent steady increase in the number of dual chamber pacemaker implantation in our centre and this is fast becoming the pacing mode of choice in some centres in West Africa [13] as it is in most developed countries [5, 14]. Complications observed in this series were acute lead dislodgement, pacemaker pocket hematoma and pneumothorax in one patient each. Lead repositioning was successfully done in the patient with lead displacement. The pacemaker pocket hematoma and pneumothorax were evacuated with satisfactory outcomes. All three complications occurred in patients who had single chamber pacemaker implantation however this was not statistically significant (p-value 0.186). This supports Aggarwal´s [16], finding of no difference in early complication rate between dual and single chamber systems. There was no procedure related mortality and most of the patients are being followed up in the pacemaker clinic.
Elderly hypertensive patients with complete heart block are the most common indication for permanent pacemaker implantation in our environment. The implantation procedure is safe (regardless of the device type) with minimal complications and satisfactory outcomes.
What is known about this topic
- Complete heart block is the commonest indication for permanent pacemaker insertion (PPI) in the West African sub-region;
- Syncope is the most frequent clinical indication for PPI.
What this study adds
- Easy fatiguability is fast becoming a prominent presenting symptom in patients who eventually require PPI;
- There is a steady increase in the number of dual chamber pacemaker implantation in West Africa.
The authors declare no competing interests.
UUO and OOO conceived and designed the study. UUO, OOO, OJE and AEO handled data collection. OOO handled data entry. OOO and UUO handled data analysis and interpretation. UUO and OOO drafted the manuscript. UUO, OOO, OJE, AEO and AOA revised and edited the manuscript. All authors read and approved the final draft of the manuscript for publication.
Table 1: patient characteristics, indication and complications
Table 2: complications based on type of device
- Fuster V, Walsh RA, O'Rourke RA, Poole-Wilson P, editors. Hurst's the Heart. New York: McGraw-Hill. 2007; 12th ed:1020-5. Google Scholar
- Thomas MO, Oke DA, Ogunleye EO, Adeyanju FA. Bradypacing: indications and management challenges in Nigeria. Pacing Clin Electrophysiol. 2007;30(6):761-763. PubMed | Google Scholar
- Tamatey MN, Sereboe LA, Tettey MM, Entsua-Mensah K, Gyan B, Aniteye EA et al. Permanent pacemaker implantation in Accra, an 18-year review. Afr Ann Thorac Cardiovasc Surg. 2012;7(2). Google Scholar
- Ekpe EE, Aghaji MA, Edaigbini SA, Onwuta CN. Cardiac pacemaker treatment of complete heart block in Enugu a 5-Year Review. Niger J Med. 2008;17(1):7-12. PubMed | Google Scholar
- Mond HG, Proclemer A. The 11th World survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009: a World Society of Arrhythmia´s project. Pacing Clin Electrophysiol. 2011;34(8):1013-1027. PubMed | Google Scholar
- Goldberger Z, Lampert R. Implantable cardioverter-defibrillators: expanding indications and technologies. JAMA. 2006;295(7):809-18. PubMed | Google Scholar
- Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR et al. Management of cardiac device infections. JACC. 2007;49:1851-9. Google Scholar
- Thomas MO, Ogunleye EO, Olusoji OO, Olugbemi A, Ojo OO. Bradyarrythmias: a study of anthropometric, demographic and comorbidity profiles in an African population. WJCS. 2013; 3:209-214. Google Scholar
- Nowak B, Misselwitz B, IoQAH Expert committee pacemaker,Erdogan A, Funck R, Irnich W et al. Do gender differences exist in pacemaker implantation? Result of an obligatory external quality control program. Europace. 2010;12:210-5. PubMed | Google Scholar
- Adeoye PO, Okonta KE, Salami MA, Adegboye VO. Experience with permanent pacemaker insertion at the University College Hospital, Ibadan, Nigeria. Nig J Cardiol. 2013;10:3-5. Google Scholar
- Aktoz M, Ucar MF,Yilmaztepe MA,Taylan G, Altay S. Gender differences and demographics and type of cardiac device over a 10-year period. Niger J Clin Pract. 2018;21:27-32. PubMed | Google Scholar
- Bradshaw PJ, Stobie P, Knuiman MW, Briffa TG, Hobbs MS. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open heart. 2014;1:e000177. PubMed | Google Scholar
- Falase B, Sanusi M, Johnson A, Akinrinlola F, Ajayi R, Oke D. Analysis of a five-year experience of permanent pacemaker implantation at a Nigerian Tertiary Hospital: need for a national data base. PAMJ. 2013;16:16. PubMed | Google Scholar
- Proclemer A, Zecchin M, D´Onofrio A, Botto GL, Facchin D, Rebellato L et al. The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association of Arrhythmology and Cardiac Pacing: Annual report 20 Giornale italiano di cardiologia. 2016;17:95-107. PubMed | Google Scholar
- Thiam M, Fall PD, Gning SB, Ott D, Gueye PM, Wade B, Perret JL. Cardiac pacing in West Africa: feasibility, problems and perspectives. Ann Cardiol Angeiol (Paris). 2003;52(4):212-214. PubMed | Google Scholar
- Aggarwal RK, Connelly DT, Ray SG, Ball J, Charles RG. Early complications of permanent pacemaker implantation: no difference between dual and single chamber systems. Br Heart J. 1995;73(6):571-575. PubMed | Google Scholar