Tracheal rupture after misplacement of Sengstaken-Blakemore tube
Adriá Rosat, Emilio Martín
Corresponding author: Adriá Rosat, Department of General Surgery, Hospital Universitario Nuestra Señora de Candelaria, Ctra, Del Rosario 145, 38010 Sta, Cruz de Tenerife, Spain
Received: 18 Jan 2016 - Accepted: 31 Jan 2016 - Published: 29 Feb 2016
Domain: Clinical medicine
Keywords: Tracheal rupture, hematemesis, Sengstaken-Blakemore
©Adriá Rosat et al. Pan African Medical Journal (ISSN: 1937-8688). This is an Open Access article distributed under the terms of the Creative Commons Attribution International 4.0 License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Cite this article: Adriá Rosat et al. Tracheal rupture after misplacement of Sengstaken-Blakemore tube. Pan African Medical Journal. 2016;23:55. [doi: 10.11604/pamj.2016.23.55.8890]
Available online at: https://www.panafrican-med-journal.com//content/article/23/55/full
Tracheal rupture after misplacement of Sengstaken-Blakemore tube
Adriá Rosat1,&, Emilio Martín2
1Department of General Surgery, Hospital Universitario Nuestra Señora de Candelaria, Ctra, Del Rosario 145, 38010 Sta, Cruz de Tenerife, Spain, 2Department of Thoracic Surgery, Hospital Universitario Nuestra Señora de Candelaria, Ctra, Del Rosario 145, 38010 Sta, Cruz de Tenerife, Spain
&Corresponding author
Adriá Rosat, Department of General Surgery, Hospital Universitario Nuestra Señora de Candelaria, Ctra, Del Rosario 145, 38010 Sta, Cruz de Tenerife, Spain
A 62-year-old man was admitted in our hospital's emergency room for hematemesis. He had a known history of alcoholic liver cirrhosis with severe esophagitis and previous episodes of hematemesis. The endoscopy showed no varix or perforation but an active bleeding from multiple ulcerations which cannot be controlled. An attempt to achieve hemostasis by balloon tamponade was undertaken using a Sengtaken-Blakemore tube. During insertion of the catheter, the patient became agitated and respiratory distress was noted when all ballons were inflated. The balloon were immediately deflated and a chest X-ray was performed, showing the tube in the right bronchus airway (A), so it was withdrawn. Right pneumothorax appeared and was treated with an intercostal drainage. The patient required orotracheal intubation and a CT scan was performed to show the rupture level (B). The patient underwent surgery and the trachea was successfully repaired. The Sengstaken-Blakemore was withdrawn and esophagoscopy was performed showing no bleeding. The patient was extubated 12 hour after the intervention. Endoscopic examination of the tracheal suture on the 11th postoperative day demonstrated normal healing and the patient was discharged two days later. The use of balloon tamponade for hemostasis in upper digestive tract has long been associated with numerous complications. The most common complication is rupture of the esophagus but respiratory complications can result from laryngeal or tracheal ischemia due to compression. Iatrogenic acute tracheal rupture is the less frequent of them. The presence of respiratory distress before the balloons were inflated could have avoided the misplacement.
Figure 1: A): chest x-ray showing Sengstaken-Blakemore tube in the right bronchus just after balloon were deflated (arrow points the tip); B): chest CT scan showing right pneumothorax with chest tube, pneumomediastinum and orotracheal tube with the tracheal rupture level